Troubleshooting of Vacuum Laminator
2022-07-20 15:04
Vacuum laminators have developed rapidly in recent years, and the automated production of printed circuit boards and copper clad laminates has placed very high demands on lamination technology: factors such as temperature, pressure and parallelism of the board. The vacuum laminator not only provides customers with specific production line design and optimized lamination process, but also provides advanced lamination concepts and high-quality products. When the vacuum laminator machine failure, we should timely maintenance, in order to extend the life of the equipment and prevent accidents. In fact, there are certain tips for troubleshooting the vacuum laminator, and the small series are as follows:
1., the first external and then internal: the hydraulic press of the vacuum laminator is a mechanical, hydraulic and electrical integration equipment, so the occurrence of the fault must be reflected comprehensively from the three. Therefore, maintenance personnel are required to master the principle of first external and then internal, that is, when the vacuum laminator fails, maintenance personnel should use methods such as looking, smelling, listening and asking to check one by one from the outside to the inside.
2. Mechanical before electrical: Because the vacuum laminator is a kind of advanced mechanical processing equipment with high degree of automation and complex technology. The mechanical fault of vacuum laminator is easy to find, and the system fault diagnosis is more difficult.
3. Static first and then move "The maintenance personnel of the vacuum laminator should be static first and then move, and should not blindly start work. They should first ask the operator about the process and state of the failure, and check the instructions and data of the vacuum laminator before starting to find the cause of the failure, and then eliminate the failure,
4. First public and then private: the utility problem of the vacuum laminator will affect the overall situation, while the special problem only affects the local.
5. The first simple and then complex: When the vacuum laminator has a variety of faults intertwined to cover up, temporarily unable to start, should first solve the easy problem, after solving the larger problem. Often in the process of solving simple faults, difficult problems may also become easier. Clear up the thinking and make the more difficult problems easier.
First general and then special: when eliminating a fault of the vacuum laminator, the most common possible causes should be considered first, and then the special causes that rarely occur should be analyzed.

Because the lamination system (vacuum laminator) used to produce printed circuit boards is more precise than ordinary vacuum laminators, and the temperature is as high as 400 degrees, the usual modification and maintenance must be done well. We have a wealth of printed circuit board Process knowledge. The model can meet various needs from small special production to large-scale continuous production. By integrating the specific lamination needs of our customers, we can provide reliable and durable solutions.
Previous Page
Next Page
Previous Page
Next Page
More news
Jiangsu Shengyi High Frequency Communication Substrate Project Foundation Laying Ceremony Held
2024/03/01
2024/03/01
Jiangxi Jiujiang PCB Project Formed a Complete Industrial Chain
2024/03/01
Service Hotline
8615989495260
Add: No.21,6/F. FuHong Bldg.No.120 Yongfu road,Qiaotou community, Fuhai street, Baoan district,Shenzhen P.R. China
Telephone: 86 - 755 - 26400459
Fax: 86 - 755 - 26487289
Mobile phone: Mr. Li 86 - 15989495260
Email:limiao@szvstar.com ericzhao@szvstar.com
Mobile website
Focus on us
Copyright©2023 All rights reserved of Shenzhen V-STAR Industry & Trade Co.,LTD.